TowerShed Systems | Dry Coolers Inc.

Dry Coolers Inc.

Industrial Process Cooling Systems

Dry Coolers, Inc.
575 South Glaspie Street
Oxford, MI 48371 USA

1-800-525-8173

TowerShed Systems

Brochure Code
OMR-1205
TowerShed - Evaporative Cooling Tower Systems
Outdoor Mechanical Room
  • Save Plant Floor Space
  • Reduce Noise and Heat
  • Installs Easily
Aqua-Evap™ OMR Series are designed to match the footprint of the cooling tower for a compact and attractive housing for mechanical cooling equipment.
Valuable production floor space should be reserved for production equipment. A cooling tower system is a vital utility that can be safely and efficiently located outside your building. An "Outdoor Mechanical Room" secures your cooling system in an attractive weather-resistant enclosure. Engineered packages install easily and can be relocated in the future without difficulty.
What's Inside:
  • Heat, light and insulation.
  • Ample space for pumps, tanks, and heat exchangers
  • Electrical control panel - wired and tested
  • Filtration equipment
  • All necessary valves and instrumentation
  • See reverse for standard features and models.
Equipment description:

Enclosure includes engineered structure to support the tower, removable galvanized exterior panels with 1” wall insulation, two (2) 120V cage lights with switch, steel door with lock and keyset, and electric heater to prevent freezing.
Pump station includes one (1) process pump, diverting valve, stainless steel tank, makeup water valve, overflow, bleed line, piping with valves, gauges, and control panel. Fully assembled, tested, wired, painted, sided, inspected, and ready for shipment.
Options:

Duplex pump includes full capacity standby pump with automatic switchover on loss of pressure. Pre-piped, wired, tested.
CyClean filtration includes factory mounted cyclone separator and bag filter for continuous full stream filtration of the cooling tower water.
Fully customized designs including heat exchangers, closed loop process systems, remote panel control and alarm indication.
  1. Pump runs continuously providing cool water to the heat source.
  2. Thermostatically controlled tower bypass valve and cooling fan main tain temperature. 
  3. When valve is in bypass mode, all water drains from tower back inside enclosure to prevent freezing.
  4. Inside of enclosure is lighted and heated.
CAPACITIES and DIMENSIONS
Note: Nominal Ton = 15,000 BTU/hr. Based on 78°F wet bulb ambient air and 95°F entering, 85°F leaving, 3 gpm/ton.
Dimensions are subject to change. Consult factory for certified drawings. Consult factory for larger sizes.
 
MODEL NO. NOM
TONS
FLOW
RANGE
(GPM)
SYSTEM
WEIGHT w/
TOWER (LBS)
WIDTH LENGTH HEIGHT w/TOWER TANK VOLUME (GAL) PUMP HP PIPE SIZE
OMR-219 146-219 400-600 22800 12'0” 8'-9” 19'-10' 1300 25 4”
OMR-282 200-282 601-800 27000 12'0” 8'-9” 23'-8” 1500 30 6”
OMR-425 296-425 801-1200 33800 12'0” 12'-8” 23'-8” 1800 50 6”
Download Brochure (360.42 KB)